hearTest - CE-certified digital audiometer
hearTest is a certified digital audiometer that combines the capabilities of a traditional clinical audiometer with the convenience of mobile testing. Engineered for accuracy and convenience, hearTest is your go-to solution for comprehensive hearing loss assessments.
hearTest integrates with our cloud-based data management portal, ensuring a seamless experience for referral, data management and reporting.
What makes hearTest the preferred choice for healthcare professionals and clinical trials?
Cutting-edge mobile hearing testing
Features that you can benefit from
- Conditioning functionality
- Test reliability metrics
- Patient signature for consent
- Audiogram and degree of loss classification
- Narrow band masking
- Downloadable PDF reports
What sets hearTest apart?
We comply with international standards and regulations
IEC 60645-1
Equipment for pure-tone audiometry.
ANSI S3.6
Specification for audiometers.
ISO 8253-1
Pure-tone air conduction audiometric test methods.
ISO 389 Series
Reference zero for the calibration of audiometric equipment.
United States of America
29 CFR PART 1910.95
South Africa
SANS 10083 SANS 10154-1
Australia
hearTest is entered in the ARTG. (443797)
Registrations and certifications
Europe
(CE-marked)
USA
(FDA Registered)
AUS
(TGA Certified)
Customer testimonials
Take data management to the next level with mHealth Studio
hearTest is launched from mHealth Studio, which allows seamless synchronization between the smart device and hearTest, ensuring all test and patient records are accessible from the cloud. mHealth Studio is included for free with your purchase of any hearX® software. It allows for data capturing, management, surveillance, referrals, report generation and secure usage anywhere, anytime.
What's in the box?
Frequently Asked Questions
Can the hearTest protocols be changed?
Can hearTest be used on any device?
With which standards does hearTest comply?
- **IEC 60645-1**: Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
- **ANSI/ASA S3.6**: Specification for Audiometers (type 4 audiometer)
- **ISO 8253-1**: Acoustics, Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry
- **ISO 389 series**: Acoustics, Reference zero for the calibration of audiometric equipment - Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones
- **BS EN ISO 13485**: Medical devices - Quality management systems - Requirements for regulatory purposes
- **IEC 60601-1-2**: Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
- **BS EN ISO 14971**: Medical devices: Application of risk management to medical devices
- **EN 62366-1**: Medical Devices - Part 1: Application of usability engineering to medical devices
- **IEC 62304**: Medical device software - Software life cycle processes
- **EN ISO 14155**: Clinical investigation of medical devices for human subjects - Good clinical practice
- **ISO 20417**: Information supplied by the manufacturer with medical devices
- **EN ISO10993-1**: Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
Does hearTest allow testing at 0 dB?
Can hearTest be used outside a booth?
Published articles that feature hearTest
Leave your details. Let us contact you.
FIll out the form below if you want to learn more about our latest clinically-validated digital audiometry solutions, tailored for you.
By submitting my details, I hereby give consent to hearX® to process my personal information as provided and contact me, for the purposes of direct marketing, including by means of text message and electronic communication in respect of information and communications related to goods and services offered by hearX®. Privacy Policy